Name : Power and Energy Reference Standard
Application : Measurement Laboratory
Accuracy : 0.02%, 0.05%
Usage : energy meter test bench
LCD : 8.4in TFT touch color LCD
Voltage : 0-576V
Current : 0-120A
Frequency : 40-70Hz
Weight : 12KG
Color : Gray
The GF333B is a three phase reference standard meter which has been especially developed for universal laboratory and test area use. It is intended for checking and calibration of reference standard power and energy meters, for calibration of precision current and voltage sources and for verification of electrical standard measurements and electricity meter test systems.
The three phase reference standard meter uses analogue - digital converters (ADCs) for its data acquisition, these being controlled and read by a digital signal processor (DSP).
The three phase reference standard meter may be directly connected to an external computer system over its RS 232 C serial interface.
The three phase reference standard meter is distinguished by having very wide measuring ranges for all AC values while still being of accuracy class 0.02%:
Voltage: 0 V ... 600 V
Current: 0A ... 120 A.
In addition, low currents from 1 mA are measured. Range selection may be made either manually or automatically.
GF333B is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the field and in the laboratory.
Electrical parameters | |
---|---|
Accuracy | 0.05% or 0.02% |
Voltage supply | 220V±10% or 110V±10%, 50/60Hz |
Voltage measurement | |
Range | 5V-480V |
Error | ±0.02% (50V-480V), ±0.05% (5V-50V) |
Display range | 5.000000V-480.0000V |
Harmonic | 2nd-63st |
Current measurement | |
Range | 1mA-120A |
Error | ±0.02% (0.2A-120A), ±0.05% (1mA-0.2A) |
Display range | 1.000000mA-120.0000A |
Power measurement | |
Active power | ±0.02% (0.2A-120A) ±0.05% (0.01A-0.2A) ±0.1% (0.001A-0.01A) |
Reactive power | ±0.05% (0.2A-120A), ±0.1% (0.001A-0.2A) |
Apparent power | ±0.05% (0.2A-120A), ±0.1% (0.001A-0.2A) |
Energy error | |
Active energy | ±0.02% (0.2A-120A) ±0.05% (0.01A-0.2A) ±0.1% (0.001A-0.01A) |
Reactive energy | ±0.05% (0.2A-120A), ±0.1% (0.001A-0.2A) |
Apparent energy | ±0.05% (0.2A-120A), ±0.1% (0.001A-0.2A) |
Phase measurement | |
Range | 0°-360° |
Error | ±0.005° |
Display range | 0.0001°-359.99° |
Frequency measurement | |
Range | 45-65Hz |
Display range | 45.0000-65.0000 |
Accuracy | 0.002Hz |
Power Factor measurement | |
Range | -1.0 ~ 0 ~ +1.0 |
Resolution | 0.0001 |
Accuracy | 0.0005 |
Energy pulse | |
High frequency output(CH) | 12000Hz |
Low frequency output(CL) | 5000Hz |
Pulse ratio | 1:1 |
Output level | 5V |
Input level | 5V |
Input frequency | Max. 1MHz |
Mechanical parameters | |
Dimensions (W×H×D) (mm) | 480×138×486 |
Weight (kg) | 10 |
Environmental conditions | |
Ambient temperature | -10°C to 45°C |
Influence of external fields | ≤0.05 %/mT |
Relative humidity | 10%-80% |
![]() |