Sign In | Join Free | My entremaqueros.com
China Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. logo
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.
Active Member

8 Years

Home > Instrument Current Transformer >

Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Contact Now

Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A

Brand Name : GFUVE

Model Number : GF106T-1000A

Certification : CE, UL, ISO9001, KEMA

Place of Origin : BEIJING CHINA

MOQ : 1set

Price : USD10000-20000/set

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 200sets

Delivery Time : 1-2weeks

Packaging Details : standard export wooden box

NAMES : Instrument Current Transformer calibration

APPLICATION : TEST CURRENT TRANSFOREMR ERROR

RATIO : 1-5000

PHASE : 4 min

ACCURACY : 0.2%

Weight : 22kg

1000A cable : 4m length

Display LCD : 6.4 inch

Contact Now

Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A

GF106T Portable Instrument Current Transformer calibration Device with turn ratio 5000/1 to 25000/5A

GF106T Portable Instrument Current Transformer calibration device is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity
4. 5% and 10% error curve 4. Withstand test of power frequency alternating current
5. Current Injecting 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Withstand test of power frequency alternating current 7. Actual secondary load test 
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test 
10. Resistance test 

PARAMETERS

Electrical parameters
Accuracy 0.2%, 0.5%
Power supply AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output 0-2500Vrms,
Excitation current output 0-5Arms (20A peak-value)
Large current output 0-1000A
Electrical parameters - continued
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurement Range 0.1-300Ω
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurement Accuracy ±4min
Resolution 0.01min
CT ratio error measurement Range ≤25000A/5A(5000A/1A)
Accuracy ≤0.5%
PT ratio error measurement Range 1-500KV
Accuracy ≤0.5%
Standards 
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters 
Overall dimension (L x W x H) (mm) 400 x 250 x 250
Weight (kg) ≤22
Environmental conditions 
Relative humidity 90RH%
Operating temperature -10°C to +40°C
Altitude ≤1000m

Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A


Product Tags:

current potential transformer

      

electromagnetic potential transformer

      
 Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A Manufactures

Portable Instrument Current Transformer Calibration Device With Turn Ratio 5000/1 To 25000/5A Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)