Brand Name : GFUVE
Model Number : GF6019 1000V30A 0.02%
Certification : CNAS CE ISO9001, ISO17025
Place of Origin : BEIJING CHINA
MOQ : 1set
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 200sets/month
Delivery Time : 7 days
Packaging Details : standard export wooden box
PRODUCT NAME : Programmable DC Power Calibrator
APPLICATION : Testing DC voltage meter, DC current meter & DC power meter
Current range : 0-30A
Voltage range : 0-1000V
accuracy : 0.02%
Function : Programmable DC voltage calibrator, DC current calibrator
Stability : 0.005%/1min
Usage : ISO17025 laboratory
Weight : 12kg
Ripple contents : ≤1%
GF6019 Programmable DC Power Calibrator for calibration of DC voltage meter, DC current meter & DC power meter
Electrical parameters | |
---|---|
Accuracy | 0.02% |
Power Supply | One Phase AC 180-265V, frequency 50/60Hz. |
DC Voltage Output | |
Range | 65V, 250V, 500V, 750V, 1000V (max 1150V) |
Adjustment range | (0-120)%RG(1) |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.1% (Non-capacitive load) |
Output load | 50VA |
Full load regulation rate | ≤±0.01%RG |
Accuracy | ±(0.03%RD+0.02%RG) |
DC Current Output | |
Range | 0.001A, 0.005A, 0.02A, 0.05A, 0.2A, 1A, 3A, 10A, 20A, 30A, (max 36A) small signal 2.5mV, 20mV, 100mV, 1V, 5V |
Adjustment range | (0-120)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s, small signal 2uV/min |
Distortion | ≤0.1% (Non-capacitive load) |
Output load | 1200VA |
Full load regulation rate | ≤±0.01%RG |
Accuracy | ±(0.02%RD+0.02%RG) |
Externally attached shunt | 100mV |
Accuracy | ±(0.02%RD+0.02%RG) |
DC Power Output | |
power output stability | <0.01%RG/120s |
power accuracy | ±(0.02%RD+0.02%RG) |
DC Power Energy Measurement Error | |
power energy | ±(0.02%RD+0.02%RG) |
Power Pulse Output | |
Power Pulse Output | 20KHz (Full-Range) |
Power Pulse Input | |
Energy pulse input | 20KHz |
Ripple output | 20-500Hz ripple output |
Communication port | USB port, RS232, 10/100M LAN |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 430x400x250 |
Weight (kg) | 12 |
Environmental conditions | |
Ambient temperature | -10°C to +40°C |
Relative humidity | -30°C to 60°C |
(1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |
PHOTO
![]() |
Programmable DC 30A 1000V Power Calibrator Images |