Sign In | Join Free | My entremaqueros.com |
|
Brand Name : GFUVE
Model Number : GF106T
Certification : CE, UL, ISO9001, KEMA
Place of Origin : BEIJING CHINA
MOQ : 1set
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 1000sets/Month
Delivery Time : 1-2weeks
Packaging Details : Standard export wooden box
NAMES : Instrument Current Transformer calibration
APPLICATION : TEST CURRENT TRANSFOREMR ERROR
RATIO : 1-5000
PHASE : 4 min
ACCURACY : 0.2%
Weight : 22kg
1000A cable : 4m length
Display LCD : 6.4 inch
GF106T Current Transformer Calibration Device With Turn Ratio Transformer Test CT PT Analyzer
GF106T Portable Instrument Current Transformer calibration device is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.
I. Current Transformer (CT) | II. Voltage Transformer (PT) |
---|---|
1. Magnetization curve | 1. Excitation characteristic test |
2. Transformation ratio test | 2. Transformation ratio test |
3. Polarity | 3. Polarity |
4. 5% and 10% error curve | 4. Withstand test of power frequency alternating current |
5. Current Injecting | 5. Degauss |
6. Degauss | 6. Calculation of knee point value |
7. Withstand test of power frequency alternating current | 7. Actual secondary load test |
8. Automatic calculation of excitation knee point value | 8. Resistance test |
9. Actual secondary load test | |
10. Resistance test |
Electrical parameters | ||
---|---|---|
Accuracy | 0.2%, 0.5% | |
Power supply | AC 220V±10% or AC 110V±10%, 50/60Hz | |
Excitation voltage output | 0-2500Vrms, | |
Excitation current output | 0-5Arms (20A peak-value) | |
Large current output | 0-1000A | |
Electrical parameters - continued | ||
Accuracy | ≤0.5% (0.2%RD+0.3%RG) | |
Secondary winding DC resistance measurement | Range | 0.1-300Ω |
Accuracy | ≤0.5% (0.2%RD+0.3%RG) | |
Secondary actual load measurement | Range | 5VA-1000VA |
Accuracy | ≤0.5% (0.2%RD+0.3%RG)±0.1VA | |
CT/PT phase error measurement | Accuracy | ±4min |
Resolution | 0.01min | |
CT ratio error measurement | Range | ≤25000A/5A(5000A/1A) |
Accuracy | ≤0.5% | |
PT ratio error measurement | Range | 1-500KV |
Accuracy | ≤0.5% | |
Standards | ||
Reference standards | GB1207-2006, GB1208-2006, GB16847-1997 IEC60044-1, IEC60044-6, IEC61869-2-2012 | |
Safety standards | GB 4793.1-2007 | |
EMC | EMC standard 89/336/EEC | |
FCC Subpart B of Part 15 Class A | ||
IEC 1000-4-2 /3 /4 /6 | ||
Mechanical parameters | ||
Overall dimension (L x W x H) (mm) | 400 x 250 x 250 | |
Weight (kg) | ≤22 | |
Environmental conditions | ||
Relative humidity | 90RH% | |
Operating temperature | -10°C to +40°C | |
Altitude | ≤1000m |
Photo
![]() |
Current Transformer Calibration CT PT Analyzer 4 Min Phase With 6.4 Inch LCD Display Images |