Sign In | Join Free | My entremaqueros.com
China Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. logo
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.
Active Member

8 Years

Home > Electric Meter Calibration >

65Hz RS485 Port Electric Meter Calibration 45VA One Phase

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Contact Now

65Hz RS485 Port Electric Meter Calibration 45VA One Phase

Brand Name : GFUVE

Model Number : GF302D

Place of Origin : BEIJING,CHINA

MOQ : 1SET

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 1500SETS/MONTH

Delivery Time : 1-2WEEKS

Packaging Details : CARTON

accuracy : 0.05%, 0.1%

power supply : One Phase AC 180-265V, frequency 50/60Hz.

voltage output range : 57.7V, 100V, 220V, 380V

current output range : 200mA, 1A, 5A, 20A, 100A

each phase output load : 45VA

frequency : 45Hz-65Hz

harmonic : 2-51times

dimension : 500x600x175MM

weight : 27KG

harmonic content : 0-40%

Contact Now

Electrical parameters 
Accuracy 0.05%, 0.1%
Power Supply One Phase AC 180-265V, frequency 50/60Hz.
AC Voltage Output 
Range(U1,U2,U3) 57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional)
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.3% (Non-capacitive load)
Output load each phase 25VA
Measuring accuracy 0.05%RG
AC Current Output 
Range(I1,I2,I3) 200mA, 1A, 5A, 20A, 100A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.3% (Non-capacitive load)
Output load 45VA
Accuracy 0.05%RG
Power Output  
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.05%RG
Reactive power measuring accuracy 0.1%RG
Phase Output  
Output adjustment range 0°-359.999°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.05°
Power Factor 
Adjustment range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0. 0005
Frequency Output  
Adjustment range 45Hz-65Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.005Hz
Voltage /Current/Harmonic Setting 
Harmonic number 2-51times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error 
Active power energy 0.05%RG
Reactive power energy 0.1%RG
Power Pulse Output  
Power pulse type active pulse, reactive pulse
Active power pulse output 5V, 10mA
Power Pulse Input 
Energy pulse type support active and reactive pulse, the highest frequency power pulse input is 180K.
Mechanical parameters 
Dimensions (W×D×H) (mm) 500x600x175
Weight (kg) About 27

65Hz RS485 Port Electric Meter Calibration 45VA One Phase


Product Tags:

RS485 Port Electric Meter Calibration

      

65Hz Electric Meter Calibration

      

Electric Meter Calibration 45VA

      
 65Hz RS485 Port Electric Meter Calibration 45VA One Phase Manufactures

65Hz RS485 Port Electric Meter Calibration 45VA One Phase Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)